T. Ching, A.C.I. van Steen, D. Gray-Scherr, J.L. Teo, A. Vasan, J. Jeon, J. Shah, A. Patel, A.E. Stoddard, J.L. Bays, J. Eyckmans, C.S. Chen
Lab Chip, (2025) 25 (6): 1474–1488. [Paper Link]
Every organ-on-chip needs to connect to pumps and reservoirs, and this is still done with tubing and fittings, one connection at a time. Connecting a single 6-channel chip to a pump and bubble traps takes 24 pieces of tubing and 36 fittings. It's slow, it's easy to plug something into the wrong port, and the setup is too bulky to fit inside a Petri dish. This is known as the "world-to-chip" problem, and the field has mostly accepted it.
I took inspiration from electronics. Instead of wiring every component by hand, electronics use flat ribbon cables that carry many connections at once. TapeTech does the same for fluids. I cut double-sided tape and thin plastic film on a desktop cutting plotter (under $400) and stack the layers into a flat, flexible ribbon with all the channels built in. One ribbon connects every channel of a chip to the pump in a single step, and it bends over the edge of a Petri dish so the whole setup stays enclosed and sterile.
Making a TapeTech ribbon only needs a 2D drawing, no molds or cleanroom. A desktop cutting plotter cuts the layers from thin PET film and double-sided tape, and alignment holes let the layers stack precisely on a simple jig. After pressing the layers together, adding small reservoirs, and a short bake, the ribbon is ready. Connecting it to a chip takes just a few minutes: I place the chip in a jig, peel off the tape liner, drop the ribbon onto the alignment pins, and press it down. Then I fill the channels with a pipette. A small vent hole above each inlet lets air escape while surface tension keeps the liquid in, so the channels fill without bubbles. A strip of tape seals all the vents at once, and the chip is ready to run. Because nothing is plugged in, the cells never feel a pressure surge.
We used TapeTech to grow blood vessel cells under flow, and the cells aligned with the flow and switched on the expected genes, just as they do in the body. We also used it to stretch the membrane in a commercial lung chip, run long-term live imaging inside a microscope stage-top chamber, and automate medium changes in a standard 6-well plate. Because the design starts as a simple 2D cut file, a new connector for a different chip can be designed and made in a few hours.
Once I had the basic ribbon working, I started building other fluidic components the same way, from tape and thin plastic film. The result is a small toolkit: flexible connectors, heat-sealed reservoir pouches, one-way valves with a thin film flap, diaphragms, multiplexers that split flow into several channels, flow chambers for cell culture, and an adapter that connects TapeTech to standard tubing. Every part is cut from flat sheets, so each one is cheap, fast to make, and easy to customize.
Combining these parts, I built a pump made almost entirely from plastic film. [Two one-way valves and a flexible diaphragm] sit in a flat, thin assembly, and a vibrating actuator presses on the diaphragm to push fluid forward. The flow rate depends on how fast it vibrates: from a trickle up to about 230 µL/min, with the peak at 28 Hz. Because it's flat and inexpensive, a pump like this could be built right into the ribbon itself, removing the need for a separate benchtop pump.