T. Ching, J. Vasudevan, S. Y. Chang, H. Y. Tan, A. S. Ranganath, C. T. Lim, J. G. Fernandez, J.J. Ng, Y.C. Toh, M. Hashimoto
Small, 18(2022) 2203426.
Blood vessels are hard to build in the lab. A good model should be freestanding, branching, multilayered, and perfusable, but no method had achieved all four at once. The main issue is that hydrogels that support living cells are very soft, usually under 100 kPa, so they are hard to print and handle.
Instead of printing the vessel directly, I 3D-printed a mold and let the vessel form inside it. The trick is that the mold is porous. I printed it from a PEGDA hydrogel and soaked it in calcium chloride, so it holds calcium ions like a sponge. When I fill the mold with an alginate-based bioink, calcium diffuses out of the mold walls and gels the bioink from the outside in. After a set dwell time, I flush out the liquid center, leaving a hollow tube. The longer the dwell time, the thicker the wall, so I could tune the wall thickness from about 200 to 550 µm in under a minute.
The two halves of the mold sit in a rigid frame, with grooves for tubing and small O-rings to seal the ends. After the vessel forms, I open the mold and lift it out with the tubing already attached, ready to connect to a pump.
The shape of the mold sets the shape of the vessel, so I could make straight vessels, bifurcations, multibranching networks, an aortic arch, and even a 3D vascular tree that splits from one inlet into nine branches. By flowing different bioinks in one after another, I built vessels with up to four layers. Adding PEGDA to the outer layer let me tune the stiffness from about 28 kPa to 1.7 MPa, matching real arteries. I grew smooth muscle cells in the wall and endothelial cells on the inner surface for 10 days under flow, and the endothelium responded to inflammation the way real vessels do.
Because the vessels are freestanding, I could stretch them on an inflating balloon to mimic a beating heart. I also designed vessels with a narrowing to mimic a blocked artery, and deployed drug-eluting balloons and stents inside them. These were proof-of-concept demonstrations, not validated tests of the devices. The vessels used here were softer than real arteries. The goal was to show what this approach could make possible in the future: lab-grown vessel models for testing medical devices before moving to animal studies.